XPF Series

Model: XPF Series
Voltage: 60V
Current: 10A - 20A
Power: Up to 420W per output (840W total)
Overview: Benchtop power supply featuring dual isolated outputs.
  • Overview +


    Sorensen XPF Series
    The Sorensen XPF is a new type of bench power supply designed to meet the need for flexibility in the choice of voltage and current. Typically, the maximum voltage and maximum current are not required simultaneously. The PowerFlexTM design enables higher currents to be generated at lower voltages within an overall power limit envelope. This is achieved by using the latest switch-mode technology.

    The XPF60-20D are dual output DC power supplies with two completely independent and isolated outputs. If required, the outputs can be wired in series or parallel to achieve up to double the maximum voltage or double the maximum current. The new XPF60-20S is a single output version of the XPF60-20D providing 60V and 20A within its 420W power envelope.

    The XPF Series has advanced digital features while keeping its simple to operate analog controls. The series also has a remote programming option making the popular XPF perfect for some ATE applications.
    The interfaces included: LXI Class C Ethernet, GPIB, USB and RS-232/423. Please see the XPF brochure section for XPF60-20DP brochure that fully describes the advanced features.

    Key Features
    • PowerFlex design provides higher currents at lower voltages enabling one model to meet many different voltage/current requirements

    • Compact design for bench use or rack mounting (1/2 or 1/4 rack width)

    • True analog controls with digital settings locking (S-Lock)

    • Mixed-mode regulation with linear final regulation for low noise

    • Dual models have isolated voltage tracking and synchronous on/off

    • P models have GPIB, RS-232, USB and LXI compliant LAN interfaces plus duplicate rear terminals

    Protection
    • Over voltage protection per output

    • Switchable remote or local sense
  • Specifications +


    Sorensen XPF Series : Specifications
    Electrical Specifications
    Model XPF 60-10D Series XPF 60-20 Series
    Voltage range 0 V - 60 V 0 V - 60 V
    Current range 0 A - 10 A 0 A - 20 A
    Power range Up to 180 W per output, see PowerFlex power envelope graph Up to 420 W per output - see PowerFlex power envelope graph
    OVP range 10% - 110% of maximum output voltage 1 V to 66 V
    Voltage setting By coarse and fine controls
    Current setting By single logarithmic control
    Line regulation <0.01% for a 10% line voltage change.
    Load regulation Change in output for any load change within PowerFlex envelope, remote sense connected: Constant voltage: <0.01% of maximum output. Constant current: <0.05% of maximum output.
    Ripple and noise
    (20 MHz bandwidth)
    Both outputs loaded at 16V/10A , CV mode: Typically <1mVrms, <15mV pk-pk; 3mVrms max. 5mVrms max; typically <3mVrms, <15mV pk-pk, at maximum load, CV mode.
    Transient response <250µs to within 50mV of setting for a 5% to 95% load change.
    Output protection Forward protection by OVP trip. Reverse protection by diode clamp for reverse currents up to 3 A.
    Temperature coefficient Typically <100ppm/°C
    Status indication LED indication of Output On, CV, CC and Power Limit. Message on display for over-voltage trip
    Output switch Push-push switch operating electronic power control. Preset voltage and current are displayed when the output is off.
    Output terminals 4mm terminal on 19mm (0.75") pitch. 15 A max. rating 4mm terminal on 19mm (0.75") pitch. 30 A max. rating
    Sensing Remote sensing via a front panel terminal block or local sensing (at output terminals). Selection by slide switch
    Meter resolution 10 mV, 10 mA
    Meter accuracy
    Voltage 0.1% +/- 2 digit
    Current 0.3% +/- 2 digit
    General Specifications
    Model XPF 60-10D Series XPF 60-20 series
    AC Input 110 to 240 volts ±10%
    50/60Hz. Installation Category II
    Power consumption 600 VA max. 1250 VA max.
    Operating
    temperature range
    5°C to 40oC, 20 to 80% RH
    Storage range -40oC to + 70oC
    Environmental Indoor use at altitudes up to 2000m, Pollution Degree 2
    Safety Complies with EN61010-1
    EMC Complies with EN61326
    CE-marked units meet EN61010-1 and EN61326
    Dimensions (HxWxD) 210 x 130 x 375mm (1/2 rack width 3U) Single - 107 x 130 (¼ rack 3U) x 398mm
    Dual - 210 x 130 mm (½ rack 3U) x 377mm
    (size excludes feet, knobs and terminals)
    Weight 5.4 kg (11.9 lb) Single - 4.25 kg (9.35 lb), Dual - 6.3 kg (13.9 lb)
    XPF35-10 Power Envelope (each output)
    XPF 60-10

     

    XPF60-20 Power Envelope (each output)

     

    Note: Specifications subject to change without notice.
  • Diagram +


    Sorensen XT Series Diagram

    Diagram Formats
    PDF XT Diagram (185KB)
  • Manuals +

  • Brochure +

  • Get A Quote +


    XPF : Model Number Description



    Options and Accessories
    HV (Input Voltage Option) 230 VAC input factory set