XDL Series

Model: XDL Series
Voltage: 35V - 56V
Current: 1A - 5A
Power: 105W - 215W
Overview: Digitally-controlled benchtop power supply
  • Overview +


    Sorensen XDL Series II
    The Sorensen XDL series II represents the "next generation" of high performance laboratory power supplies. The XDL provides multiple ranges for increased current capability at lower voltages and uses pure linear technology. Unlike other digitally controlled units, the XDL series II provides both numeric and rotary control while the illuminated keys and display legends provide instant confirmation of settings and status.

    For added convenience the Sorensen XDL series II provides storage of up to 10 power supply set-ups in non-volatile memory (30 set-ups for a triple). There are also fully adjustable over-voltage and over-current trips. The XDL series II also provides full remote sense capability via dedicated sense terminals.

    The XDL triple output model features link and copy mode for convenience. When linked, keyboard and jog wheel control operates both outputs simultaneously. The copy function copies all settings for output 1 to output 2.
    Features And Benefits
    Key Features
    • Multiple voltage⁄current ranges

    • Direct numeric entry and incremental rotary control of voltage and current

    • Remote or local sense

    • Illuminated keys and display legends

    • Up to ten store/recall set-ups (30 set–ups for triple output)

    • Power output display

    • Link and copy mode

    Protection
    • Over voltage protection

    • Over current protection

    • Over temperature protection

    • Sense protection

  • Specifications +


    Sorensen XDL Series II: Specifications
    Output : Voltage and Current
    Model Output Range Output Range 2 Output Range 3
    35-5 1 0-35 V, 0-3 A 0-15 V, 0-5 A 0-35 V, 0-500.0 mA
    35-5T 0-35 V, 0-3 A 0-15 V, 0-5 A 0-35 V, 0-500.0 mA
    35-5P 0-35 V, 0-3 A 0-15 V, 0-5 A 0-35 V, 0-500.0 mA
    35-5TP 0-35 V, 0-3 A 0-15 V, 0-5 A 0-35 V, 0-500.0 mA
    56-4 0-56 V, 0-2 A 0-25 V, 0-4 A 0-56 V, 0-500.0 mA
    56-4P 0-56 V, 0-2 A 0-25 V, 0-4 A 0-56 V, 0-500.0 mA
    56-4TP 0-56 V, 0-2 A 0-25 V, 0-4 A 0-56 V, 0-500.0 mA
    Model Outputs Output Power Interface (GPIB/RS-232/USB)LAN-LXI
    35-5 1 105 W No
    35-5T 3 Aux, 1-6 V, 3 A 215 W No
    35-5P 1 105 W Yes
    35-5TP 3 Aux, 1-6 V, 3 A 215 W Yes
    56-4 1 112 W No
    56-4P 1 112 W Yes
    56-4TP 3 Aux, 1-6 V, 3 A 112W Yes
    Voltage Setting By floating point numeric entry or rotary jog wheel; resolution 1mV
    Current Setting By floating point numeric entry or rotary jog wheel; resolution 1mA or 0.1mA depending on range
    Voltage Setting Resolution 1mV
    Accuracy ± (0·03% + 5mV)
    Current Setting Resolution 1mA; 0·1mA on 500mA range
    Accuracy ± (0·2% + 5mA); ± (0·2% + 0·5mA) on 500mA range.
    Output Mode Operation in constant voltage or constant current modes with automatic cross-over and mode indication by LEDs.
    DC Output Switch Sets output voltage and current levels to zero when Off.
    Output Terminals 4 mm terminals on 19 mm (0.75”) spacing
    Load Regulation Voltage: < 0.01% + 2 mV Current: < 0.01% + 250 μA; < 0.01% + 50 μA on 500 mA range (measured at output terminals using remote sense)
    Line Regulation Voltage: < 0.01% + 2 mV for 10% line change Current: < 0.01% + 250 μA; < 0.01% + 50 μA on 500 mA range
    Ripple and Noise Typically < 0.35% Vrms 2 mVp-p CV mode, and < 0.2 mArms,
    < 20 μArms (500 mA range) CI mode
    Transient Response 50 μs to within 15 mV of set level for a change in load current from full load to half load or vice versa
    Temperature Coefficient <± (50 ppm + 0.5 mV) / °C (voltage)
    Remote Sense Eliminates up to 0.5 V drop per lead. Remote sense operation selected from front panel and indicated by LED
    Sense Terminals Recessed sprung sockets for direct insertion of wires. Duplicated on rear terminal block (P versions only)
    General Specifications
    Operational AC Input Voltage 115 V or 230 V ± 10% (adjustable internally, option HV for factory set 230 Vac input), 50/60 Hz. Installation Category II
    Operating Temperature Range 5 to 40°C, 20% to 80% RH
    Storage Temperature Range - 40 to 70°C
    Dimensions (H x W x D) 6.3 x 5.5 x 11.4” (160 x 140 x 290 mm) (XDL 35-5, XDL 35-5P, XDL 56-4, XDL 56-4P),
    6.3 x 11.0 x 11.4” (160 x 280 x 290 mm) (XDL 35-5T, XDL 35-5TP, XDL 56-4T, XDL 56-4TP)
    Weight 11.9 lb (5.4 kg) (XDL 35-5, XDL 56-4)
    12.1 lb (5.5 kg) (XDL 35-5P, XDL 56-4P)
    23.1 lb (10.5 kg) (XDL 35-5T, 56-4T)
    23.3 lb (10.6 kg) (XDL 35-5TP, 56-4TP)
    Benchtop Operation Folding legs are incorporated that can be used to angle the front panel upwards when required
    Rack Mount Operation 19-inch 4U mount for up to three single output units or one triple, plus one single Blanking plates available for unused sections
    Approvals CE-marked units meet: EN61010-1 and EN61326