Static Data Acquisition

  • EX1403
    EX1403 - 16-Channel bridge and strain gauge measurement instrument

    16-Channel bridge and strain gauge measurement instrument



    • 24-bit ADC per Channel
    • 102.4 ksamples/second/channel Sample Rate
    • Built-in Programmable Excitation
    • TEDS Support
    • Built-in Shunt Calibration
    • Power over Ethernet (PoE) or 10–50 V DC input
    • Built-in Parallel Data Streaming
    • IEEE-1588 Synchronization
    • Full-featured embedded web interface
    • LXI Ethernet interface
    • Compact 1U half-rack form factor

    Keep Reading
  • EX1000A – 48-Channel Precision Voltage Measurement Instrument

    48-Channel Precision Voltage Measurement Instrument



    • 48 voltage channels
    • Supports wide range of static measurements and transducer types including thermocouples, RTDs, thermistors, strain gauge, pressure transducers, etc. using EX10SC signal conditioning modules
    • Signal conditioning configurable on a per channel basis
    • Sampling rates up to 1000 Sa/sec/ch
    • Programmable low pass filter per channel
    • Standalone, compact 1U footprint
    • Voltage ranges ±10 V, ±1V, ±0.1V, ± 0.067V and ± 0.01V
    • LXI compliant with IEEE-1588 and wired trigger bus for distributed, synchronized measurements
    • Unlimited expansion for High-Channel counts
    • Built in self-test and self-calibration

    Keep Reading
  • EX1000A-TC – Thermocouple and Voltage Measurement Instrument

    48-Channel Precision Thermocouple and Voltage Measurement Instrument



    • 48 thermocouple and voltage channels
    • Very high-performance thermocouple measurements, <0.3° C accuracy
    • Supports all thermocouple types
    • Built-in cold junction compensation, open transducer detection, self-test and self-calibration
    • Supports wide range of static measurements and transducer types including thermocouples, RTDs, thermistors, strain gauge, pressure transducers, etc. using EX10SC signal conditioning modules
    • Signal conditioning configurable on a per channel basis
    • Sampling rates up to 1000 Sa/sec/ch
    • Standalone, compact 1U footprint
    • LXI compliant with IEEE-1588 and wired trigger bus for distributed, synchronized measurements
    • Unlimited expansion for High-Channel counts

    Keep Reading
  • EX1000A-TCDC – DC Powered Thermocouple and Voltage Measurement Instrument

    48-Channel Precision Thermocouple and Voltage Measurement Instrument, DC Powered



    • 48 thermocouple and voltage channels
    • Very high-performance thermocouple measurements, <0.3° C accuracy
    • Supports all thermocouple types
    • 10-34 V DC powered with extended temperature range for harsh testing in harsh environments.
    • Built-in cold junction compensation, open transducer detection, self-test and self-calibration
    • Supports wide range of static measurements and transducer types including thermocouples, RTDs, thermistors, strain gauge, pressure transducers, etc. using EX10SC signal conditioning modules
    • Signal conditioning configurable on a per channel basis
    • Sampling rates up to 1000 Sa/sec/ch
    • Standalone, compact 1U footprint
    • LXI compliant with IEEE-1588 and wired trigger bus for distributed, synchronized measurements

    Keep Reading
  • EX10SC

    16-Channel Signal Conditioning Expansion Chassis



    • 16-Channel capacity
    • Mix and match transducer types on a per-channel basis
    • Supports wide range of static measurements and transducer types including thermocouples, RTDs, thermistors, strain gauge, pressure transducers, etc. using signal conditioning modules
    • Seamless integration with the EX1000A, EX1016A, EX1032A, EX1000A-TC and EX1000A-TCDC
    • Turnkey support with EXLab Data Acquisition Software
    • 1500Vrms isolation (module)
    • 300V isolation (input to chassis)
    • nput protection to 240VAC continuous
    • ANSI/IEEE C37.90.1 transient protection

    Keep Reading
  • EX1629 - 48-Channel High Performance Strain Gauge Measurement Instrument

    48-Channel High Performance Strain Gauge Measurement Instrument



    • Supports quarter-bridge (120, 350Oor user defined), half-bridge or full-bridge
    • 24-bit ADCs, sampling rates up to 25 kSa/s
    • Built in programmable differential excitation -8V to 8V
    • Built in selectable bridge completion
    • Configure signal conditioning excitation and bridge completion on a per channel basis
    • Simple, low-cost wiring using RJ-45 telecom connectors
    • Supports TEDS for easy transducer detection and setup
    • RJ-45 input connector reduces setup cost and time
    • Built in self-calibration and shunt calibration
    • Supports voltage, ratiometric and linear measurements other than strain measurements.

    Keep Reading